ARMOURED SINGLE CORE CABLES
COPPER CONDUCTORS
STANDARD : IEC 60502-2
Uo/U(UM)=12/20(24)kV
1.
Conductor
2.
Conductor Screen
3.
XLPE Insulation
4.
Insulation Screen (Non-Metallic)
5.
Insulation Screen (Metallic)
6.
Bedding
7.
Aluminium Tape Armour
8.
Outer Sheath
Item code (1)
Size
Diameter of Conductor (Approx.)
Nominal Insulation Thickness
Diameter over Insulation (Approx.)
Number and Nominal Thickness of Steel Tape
Nominal Outer Sheath thickness
Overall Diameter (Approx.)
Weight of Cable (Approx.)
CUT
CUW
CUT
CUW
CUT
CUW
mm²
mm
mm
mm
mm
mm
mm
mm
mm
kg/km
kg/km
10
25
5.9
6.0
19.5
2x0.5
1.9
1.9
30
31
1150
1350
11
35
6.9
5.5
19.5
2x0.5
1.9
1.9
30
31
1225
1425
12
50
8.1
5.5
20.7
2x0.5
1.9
2.0
31
33
1400
1600
13
70
9.7
5.5
22.3
2x0.5
2.0
2.0
33
34
1650
1875
14
95
11.4
5.5
24.0
2x0.5
2.0
2.1
35
36
1975
2200
15
120
12.9
5.5
25.5
2x0.5
2.1
2.1
36
38
2275
2500
16
150
14.3
5.5
26.9
2x0.5
2.1
2.2
38
39
2600
2900
17
185
16.0
5.5
28.6
2x0.5
2.2
2.2
40
41
3000
3300
18
240
18.4
5.5
31.0
2x0.5
2.3
2.3
42
44
3650
3975
19
300
20.4
5.5
33.0
2x0.5
2.3
2.4
45
46
4300
4625
20
400
23.2
5.5
35.8
2x0.5
2.4
2.5
48
50
5200
5675
21
500
26.7
5.5
39.3
2x0.5
2.5
2.6
51
53
6375
6850
22
630
30.4
5.5
43.0
2x0.5
2.6
2.7
55
57
7875
8400
Size
Max. DC Resis- tance at 20°C
Inductance
Capaci- tance
Adiabatic Short Circuit Current for 1 second
Current Carrying Capacity (2)
Voltage Drop per phase
Trefoil
Flat
Cond.
CUT
CUW
CUT
CUW
Direct Buried
In Air
Direct Buried
In Air
mm²
Ohm/km
mH/km
mH/km
m
F/km
kA
kA
kA
Amps
Amps
Amps
Amps
V/A.Km
25
0.7270
0.504
0.805
0.14
3.575
0.504
2.000
164
170
165
172
0.8600
35
0.5240
0.496
0.776
0.16
5.005
0.504
2.000
197
206
197
208
0.647
50
0.3870
0.474
0.751
0.18
7.150
0.532
2.000
232
246
233
248
0.502
70
0.2680
0.452
0.724
0.20
10.010
0.569
2.000
283
305
284
308
0.376
95
0.1930
0.438
0.708
0.21
13.585
0.609
2.000
339
370
339
373
0.297
120
0.1530
0.423
0.689
0.23
17.160
0.644
2.000
385
426
385
429
0.253
150
0.1240
0.410
0.673
0.25
21.450
0.676
3.125
431
482
428
484
0.221
185
0.0991
0.391
0.657
0.27
26.455
0.716
3.125
486
551
482
552
0.192
240
0.0754
0.383
0.637
0.30
34.320
0.772
3.125
560
647
553
644
0.165
300
0.0601
0.370
0.621
0.33
42.900
0.819
3.125
628
735
618
730
0.148
400
0.0470
0.355
0.601
0.37
57.200
0.884
4.375
709
846
688
828
0.132
500
0.0366
0.335
0.586
0.40
71.500
0.965
4.375
798
972
769
945
0.1200
630
0.0283
0.333
0.569
0.45
90.090
1.051
4.375
891
1106
851
1069
0.111
The code numbers to be read in conjunction with 05020131 at the beginnng. Example for 150 mm² cable, the code number is 0502013116.
Code number for other types of insulaton screen, Replace the 6
th
digit as follows:
2 for S + CUW, 3 for B + CUT; 4 for B + CUW
LAYING CONDITIONS :
Underground temperature of soil 20°C, Ground thermal resistivity 100°C cm/W, Ambient temperature 30°C. Depth of laying = 700 mm.
XLPE INSULATED MEDIUM VOLTAGE CABLES
»
Contact Webmaster
Riyadh Cables Group of Companies - PO Box 26862, Riyadh 11496 KSA, Tel.no.9661-2651415, Fax no.9661-2651423
|
Home
|
About Us
|
Email Us
|
Contact Us
|
Site Map
|
Jobs
|
© 2008 Riyadh Cables Group of Companies : All Rights Reserved
| This page is best viewed in screen resolution 1024x768 | Developed and Designed by Riyadh Cables Webmaster :
noel.m.r.i
|