| » Cables Gallery |
| » |
Wires
|
| » |
LV Cables
|
| » |
Control Cables
|
| » |
LV Lead Sheathed
|
| » |
LSF Cables
|
| » |
MV Cables
|
| » |
MV Lead Sheathed
|
| » |
HV Cables
|
| » |
Overhead Lines
|
| » |
Telephone Cables
|
| » |
Optical Fibre Cables
|
|
|
| NOTICE!
RCGC catalogues under circulation are still valid. Some International and National Standards mentioned in RCGC Catalogues.. <more>
|
|
|
 |
 |
 |
|
|
|
|
| ARMOURED THREE CORE LEAD SHEATHED CABLE |
| COPPER CONDUCTORS |
STANDARD : IEC 60502-2 |
Uo/U (Um)=6/10(12) kV |
|
| 10 |
25 |
5.9 |
670 |
3.4 |
13.9 |
1.7 |
2.5 |
2.6 |
58 |
7800 |
| 11 |
35 |
6.9 |
929 |
3.4 |
14.9 |
1.8 |
2.5 |
2.7 |
62 |
8750 |
| 12 |
50 |
8.1 |
1260 |
3.4 |
16.1 |
1.9 |
2.5 |
2.8 |
65 |
9650 |
| 13 |
70 |
9.7 |
1820 |
3.4 |
17.7 |
2.0 |
2.5 |
2.9 |
69 |
11100 |
| 14 |
95 |
11.4 |
2518 |
3.4 |
19.4 |
2.1 |
2.5 |
3.1 |
74 |
13000 |
| 15 |
120 |
12.9 |
3175 |
3.4 |
20.9 |
2.2 |
2.5 |
3.2 |
79 |
14750 |
| 16 |
150 |
14.3 |
3919 |
3.4 |
22.3 |
2.3 |
3.15 |
3.3 |
84 |
17250 |
| 17 |
185 |
16.0 |
4902 |
3.4 |
24.0 |
2.4 |
3.15 |
3.5 |
88 |
19500 |
| 18 |
240 |
18.4 |
6443 |
3.4 |
26.4 |
2.5 |
3.15 |
3.7 |
96 |
22950 |
| 19 |
300 |
20.7 |
8069 |
3.4 |
28.9 |
2.6 |
3.15 |
3.8 |
102 |
26300 |
|
| 25 |
0.727 |
0.387 |
0.21 |
3.575 |
0.503 |
150 |
150 |
0.829 |
| 35 |
0.524 |
0.368 |
0.23 |
5.005 |
0.535 |
190 |
190 |
0.618 |
| 50 |
0.387 |
0.355 |
0.25 |
7.150 |
0.574 |
225 |
225 |
0.146 |
| 70 |
0.268 |
0.342 |
0.29 |
10.010 |
0.625 |
270 |
280 |
0.351 |
| 95 |
0.193 |
0.335 |
0.31 |
13.585 |
0.680 |
330 |
340 |
0.273 |
| 120 |
0.153 |
0.326 |
0.34 |
17.160 |
0.728 |
370 |
385 |
0.231 |
| 150 |
0.124 |
0.319 |
0.37 |
21.450 |
0.773 |
420 |
445 |
0.200 |
| 185 |
0.0991 |
0.313 |
0.40 |
26.455 |
0.827 |
470 |
510 |
0.173 |
| 240 |
0.0754 |
0.305 |
0.44 |
34.320 |
0.917 |
540 |
590 |
0.148 |
| 300 |
0.0601 |
0.297 |
0.48 |
42.900 |
0.997 |
580 |
620 |
0.131 |
|
- The code numbers to be read in conjuction with 03020123 at the beginning and "L" at the end.
Example: for 150 mm² the code number is 0302012316L
Code number for different types of insulation screen : replace the 6th digit as follows: 2 for S + CUW; 3 for B + CUT; 4 for B + CUW; 5 for G + CUT and 6 for G + CUW
- For Copper Tape screen only.
-
Laying Conditions : Underground temperature of soil 20°C, Ground Thermal resistivity 100°C cm/W,
ambient temperature 30°C.
For other laying conditions, please refer to Table nos. 1 - 5 for derating
factors.
|
| XLPE INSULATED LEAD SHEATHED MEDIUM VOLTAGE CABLES |
|
|
|
|
|
|
|
 |
 |
|
 |
|