| » Cables Gallery |
| » |
Wires
|
| » |
LV Cables
|
| » |
Control Cables
|
| » |
LV Lead Sheathed
|
| » |
LSF Cables
|
| » |
MV Cables
|
| » |
MV Lead Sheathed
|
| » |
HV Cables
|
| » |
Overhead Lines
|
| » |
Telephone Cables
|
| » |
Optical Fibre Cables
|
|
|
| NOTICE!
RCGC catalogues under circulation are still valid. Some International and National Standards mentioned in RCGC Catalogues.. <more>
|
|
|
 |
 |
 |
|
|
|
|
| UN-ARMOURED SINGLE CORE LEAD SHEATHED CABLE |
| COPPER CONDUCTORS |
STANDARD : IEC 60502-2 |
Uo/U (Um)=8.7/15(17.5) kV |
|
| 10 |
25 |
5.9 |
220 |
4.5 |
16.1 |
1.3 |
1.7 |
27 |
1700 |
| 11 |
35 |
6.9 |
305 |
4.5 |
17.1 |
1.4 |
1.8 |
28 |
1950 |
| 12 |
50 |
8.1 |
414 |
4.5 |
18.3 |
1.4 |
1.8 |
30 |
2150 |
| 13 |
70 |
9.7 |
598 |
4.5 |
19.9 |
1.4 |
1.8 |
31 |
2450 |
| 14 |
95 |
11.4 |
827 |
4.5 |
21.6 |
1.5 |
1.9 |
34 |
2950 |
| 15 |
120 |
12.9 |
1043 |
4.5 |
23.1 |
1.5 |
2.0 |
35 |
3350 |
| 16 |
150 |
14.3 |
1287 |
4.5 |
24.5 |
1.6 |
20.0 |
37 |
3850 |
| 17 |
185 |
16.0 |
1610 |
4.5 |
26.2 |
1.6 |
2.1 |
40 |
4400 |
| 18 |
240 |
18.4 |
2116 |
4.5 |
28.6 |
1.7 |
2.2 |
42 |
5300 |
| 19 |
300 |
20.7 |
2650 |
4.5 |
31.1 |
1.7 |
2.2 |
45 |
6000 |
| 20 |
400 |
23.2 |
3384 |
4.5 |
33.6 |
1.8 |
2.3 |
48 |
7200 |
| 21 |
500 |
26.7 |
4352 |
4.5 |
37.1 |
1.9 |
2.4 |
52 |
8700 |
| 22 |
630 |
30.5 |
5623 |
4.5 |
40.9 |
2.0 |
2.6 |
57 |
10700 |
|
| 25 |
0.727 |
0.470 |
0.780 |
0.17 |
3.575 |
1.961 |
165 |
170 |
0.850 |
| 35 |
0.524 |
0.456 |
0.758 |
0.19 |
5.005 |
2.223 |
195 |
200 |
0.638 |
| 50 |
0.387 |
0.435 |
0.732 |
0.21 |
7.150 |
2.343 |
230 |
245 |
0.494 |
| 70 |
0.268 |
0.415 |
0.706 |
0.23 |
10.010 |
2.504 |
280 |
305 |
0.368 |
| 95 |
0.193 |
0.402 |
0.690 |
0.25 |
13.585 |
2.877 |
335 |
375 |
0.289 |
| 120 |
0.153 |
0.389 |
0.672 |
0.27 |
17.160 |
3.039 |
385 |
425 |
0.245 |
| 150 |
0.124 |
0.377 |
0.656 |
0.29 |
21.450 |
3.414 |
430 |
485 |
0.213 |
| 185 |
0.0991 |
0.366 |
0.641 |
0.32 |
26.455 |
3.655 |
490 |
560 |
0.185 |
| 240 |
0.0754 |
0.352 |
0.621 |
0.35 |
34.320 |
4.189 |
560 |
660 |
0.159 |
| 300 |
0.0601 |
0.340 |
0.605 |
0.39 |
42.900 |
4.495 |
640 |
750 |
0.141 |
| 400 |
0.047 |
0.327 |
0.585 |
0.43 |
57.200 |
5.095 |
720 |
870 |
0.125 |
| 500 |
0.0366 |
0.318 |
0.570 |
0.48 |
71.500 |
5.870 |
810 |
1000 |
0.114 |
| 630 |
0.0283 |
0.307 |
0.554 |
0.53 |
90.090 |
6.825 |
910 |
1150 |
0.105 |
|
- The code numbers to be read in conjuction with 04020701 at the beginning.
Code number for different types of insulation screen : replace the 6th digit as follows: 7 for STRIPPABLE + LEAD; 8 for BONDED + LEAD; 9 for GRAPHITE + LEAD
Example: for 150 mm² Strippable + Lead cable, the code number is 0402070116.
-
Laying Conditions : Underground temperature of soil 20°C, Ground Thermal resistivity 100°C cm/W,
ambient temperature 30°C.
For other laying conditions, please refer to Table nos. 1 - 5 for derating
factors.
|
| XLPE INSULATED LEAD SHEATHED MEDIUM VOLTAGE CABLES |
|
|
|
|
|
|
|
 |
 |
|
 |
|